"Velkam" <velkam.trinti@gmail.com> Wrote in message: > Kadangi ansciau dyzeliu nevazinejau tai nelabai domejausi nors ne karta > maciau subj. su EGR. Dabar paciam iskilo toks dziaugsmas, bevaziuojant > siandien kamstyje uzsidege Emission Worksop. Masina Octavia 2008 > 1.9TDI. Pajungus laida rodo stai ka: > > 001025 - EGR System > P0401 - 000 - Insufficient Flow > Freeze Frame: > Fault Status: 01110000 > Fault Priority: 0 > Fault Frequency: 1 > Reset counter: 255 > Mileage: 178133 km > Time Indication: 0 > Date: 2000.00.00 > Time: 13:57:18 > > Freeze Frame: > RPM: 1428 /min > Speed: 51.0 km/h > Load: 7.8 % > Duty Cycle: 14.6 % > Duty Cycle: 100.2 % > Mass Air / Rev.: 220.0 mg/str > Mass Air / Rev.: 410.0 mg/str > > 000665 - Boost Pressure Regulation > P0299 - 000 - Control Range Not Reached > Freeze Frame: > Fault Status: 01110000 > Fault Priority: 0 > Fault Frequency: 1 > Reset counter: 255 > Mileage: 178144 km > Time Indication: 0 > Date: 2000.00.00 > Time: 16:28:02 > > Freeze Frame: > RPM: 2100 /min > Speed: 74.0 km/h > Load: 58.8 % > Voltage: 14.59 V > Bin. Bits: 00101000 > Absolute Pres.: 1856.4 mbar > Absolute Pres.: 1244.4 mbar > > Ka siais laikais daro su tais EGR. Veiksmo vieta Vilnius, jeigu ka... > Pazystamas sia problema issprende keisdamas egr, apie 500 eur su darbu garazinio, prakiuro egr radiatorius tipo -- ----Android NewsGroup Reader---- http://usenet.sinaapp.com/