kaiptai reiktu perdaryt AT maista i 14V :) "KEdas" <news.omnitel.net@-trinti-katalogai.net> wrote in message news:hjfd4n$s0m$1@trimpas.omnitel.net... > On 2010.01.23 18:45, config.lt wrote: >> a tai ko gi nepakraus pilnai? > Todėl, kad pakrautas akumas duoda 13,6V įtampą, o maitblokis – tik 12V. > Tiesą pasakius MKN maitblokis nepakraus visai. > http://www.batteryuniversity.com/partone-13.htm > Open circuit voltage > > State-of-Charge in % > Figure 3: BCI standard for SoC estimation of a 12V flooded lead acid car battery. > > Test the battery at room temperature. Allow 4-8 hour of rest after charge or discharge. > Courtesy of BCI > 12.65V-100% > 12.45V-75% > 12.24V-50% > 12.06V-25% > 11.89V or less-Discharged > Note: The BCI readings apply to flooded batteries with antimony doping. Calcium will raise the voltage by 5 - 8%. > Calcium is commonly used for maintenance-free lead acid batteries. > After charge or discharge, allow the battery to rest for a minimum of eight hours before assessing the state-of-charge > by measuring the terminal voltage.